1.7 KiB
1.7 KiB
| layout | title | permalink |
|---|---|---|
| page | EKBBF0: 11/70 MEMORY MANAGEMENT DIAGNOSTIC (PART 2) | /disks/dec/rl02k/xxdp/ekbbf0/ |
EKBBF0: 11/70 CPU DIAGNOSTIC (PART 2)
From the PDP-11 Diagnostic Handbook (1988), p. 1-7:
11/70 CPU DIAGNOSTIC PART 1
ABSTRACT:
This diagnostic is the second part of the 11/70 CPU, it tests advanced
instructions and miscellaneous logic.
OPERATING PROCEDURES:
Set the switch register by <CONTROL P> (RD console)
CON = xxxxxxWZ
(W = deposit xxxxxx into console switch register)
(R = read and type console switch settings)
(Z = switch console terminal back to program)
.R EKBBF0
SWITCH SETTINGS
SW15 = 1 halt on error
SW14 = 1 loop on test
SW13 = 1 inhibit error typeouts
SW12 = 1 inhibit T-bit trapping
SW11 = 1 inhibit iterations
SW10 = 1 ring bell on error
SW09 = 1 loop on error
SW08 = 1 loop on test in SWR <07:00>
SW07 = 1 not used
SW06 = 1 skip bus request 6 test
SW05 = 1 skip bus request 5 test
SW04 = 1 skip bus request 4 test
SW02 = 1 test selector (with switch 8)
SW01 = 1 test selector (with switch 8)
SW00 = 1 skip operator intervention testing
At the moment, PDPjs is failing a couple of tests within this diagnostic:
.R EKBBF0
EKBBF0.BIC
CEKBBF0 11/70 CPU #2
A
SCCE STACK OVERFLOW NOT GOING HIGH OR
NOT GETTING TO TMCD E31 OR E31 BAD
ERRORPC TEST NUMBER
020646 000040
CPU UNDER TEST FOUND TO BE A KB11-B/C OR KB11-CM
TMCA E67(8) NOT GETTING TO E76(13) OR E76 IS BAD
ERRORPC TEST NUMBER
026030 000063