@ -47,58 +47,76 @@ Debugger commands described below to load and execute these "toggle-ins".
Load Address 300
Exam Display = 070707 ... Relocation works
Step 1: Load ADDR register with 200:
Step 1: Load ADDRESS register with 200.
{% include machine-command.html type='clickOnce' label='LOAD 200' machine='test1170' command='script' value='set Panel SR 200;toggle Panel LOAD' %}
Step 2: Deposit 012737 at ADDR 200:
Step 2: Deposit 012737 at ADDRESS 200.
{% include machine-command.html type='clickOnce' label='DEPOSIT 012737' machine='test1170' command='script' value='set Panel SR 012737;toggle Panel DEP' %}
Step 3: Deposit 000400 at ADDR 202:
Step 3: Deposit 000400 at ADDRESS 202.
{% include machine-command.html type='clickOnce' label='DEPOSIT 000400' machine='test1170' command='script' value='set Panel SR 000400;toggle Panel DEP' %}
Step 4: Deposit 177572 at ADDR 204:
Step 4: Deposit 177572 at ADDRESS 204.
{% include machine-command.html type='clickOnce' label='DEPOSIT 177572' machine='test1170' command='script' value='set Panel SR 177572;toggle Panel DEP' %}
Step 5: Deposit 012737 at ADDR 206:
Step 5: Deposit 012737 at ADDRESS 206.
{% include machine-command.html type='clickOnce' label='DEPOSIT 012737' machine='test1170' command='script' value='set Panel SR 012737;toggle Panel DEP' %}
Step 6: Deposit 070707 at ADDR 210:
Step 6: Deposit 070707 at ADDRESS 210.
{% include machine-command.html type='clickOnce' label='DEPOSIT 070707' machine='test1170' command='script' value='set Panel SR 070707;toggle Panel DEP' %}
Step 7: Deposit 000200 at ADDR 212:
Step 7: Deposit 000200 at ADDRESS 212.
{% include machine-command.html type='clickOnce' label='DEPOSIT 000200' machine='test1170' command='script' value='set Panel SR 000200;toggle Panel DEP' %}
Step 8: Deposit 000000 at ADDR 214:
Step 8: Deposit 000000 at ADDRESS 214.
{% include machine-command.html type='clickOnce' label='DEPOSIT 000000' machine='test1170' command='script' value='set Panel SR 000000;toggle Panel DEP' %}
Step 9: Load ADDR register with 300:
Step 9: Load ADDRESS register with 300.
{% include machine-command.html type='clickOnce' label='LOAD 300' machine='test1170' command='script' value='set Panel SR 300;toggle Panel LOAD' %}
Step 10: Deposit 300 at ADDR 300:
Step 10: Deposit 300 at ADDRESS 300.
{% include machine-command.html type='clickOnce' label='DEPOSIT 300' machine='test1170' command='script' value='toggle Panel DEP' %}
Step 11: Load ADDR register with 17772300:
Step 11: Load ADDRESS register with 17772300.
{% include machine-command.html type='clickOnce' label='LOAD 17772300' machine='test1170' command='script' value='set Panel SR 17772300;toggle Panel LOAD' %}
Step 12: Deposit 077406 at ADDR 17772300:
Step 12: Deposit 077406 at ADDRESS 17772300.
{% include machine-command.html type='clickOnce' label='DEPOSIT 077406' machine='test1170' command='script' value='set Panel SR 077406;toggle Panel DEP' %}
Step 13: Load ADDR register with 17772340:
Step 13: Load ADDRESS register with 17772340.
{% include machine-command.html type='clickOnce' label='LOAD 17772340' machine='test1170' command='script' value='set Panel SR 17772340;toggle Panel LOAD' %}
Step 14: Deposit 000001 at ADDR 17772340:
Step 14: Deposit 000001 at ADDRESS 17772340.
{% include machine-command.html type='clickOnce' label='DEPOSIT 000001' machine='test1170' command='script' value='set Panel SR 000001;toggle Panel DEP' %}
Step 15: Load ADDR register with 200:
Step 15: Load ADDRESS register with 200.
{% include machine-command.html type='clickOnce' label='LOAD 200' machine='test1170' command='script' value='set Panel SR 200;toggle Panel LOAD' %}
Step 16: Set ENABLE and toggle START:
Step 16: Set ENABLE and toggle START.
{% include machine-command.html type='clickOnce' label='START' machine='test1170' command='script' value='set Panel ENABLE 1; toggle Panel START' %}
Step 17: Load ADDR register with 300:
Step 17: Load ADDRESS register with 300.
{% include machine-command.html type='clickOnce' label='LOAD 300' machine='test1170' command='script' value='set Panel SR 300;toggle Panel LOAD' %}
Step 18: Examine ADDR 300:
Step 18: Examine ADDRESS 300.
{% include machine-command.html type='clickOnce' label='EXAM' machine='test1170' command='script' value='toggle Panel EXAM' %}
Alternatively, with the PDPjs Debugger, the above "toggle-in" is easily entered with the following commands (the