diff --git a/devices/pdp11/machine/1170/panel/debugger/README.md b/devices/pdp11/machine/1170/panel/debugger/README.md index fd36680e3..7f8cce2f3 100644 --- a/devices/pdp11/machine/1170/panel/debugger/README.md +++ b/devices/pdp11/machine/1170/panel/debugger/README.md @@ -47,58 +47,76 @@ Debugger commands described below to load and execute these "toggle-ins". Load Address 300 Exam Display = 070707 ... Relocation works -Step 1: Load ADDR register with 200: +Step 1: Load ADDRESS register with 200. + {% include machine-command.html type='clickOnce' label='LOAD 200' machine='test1170' command='script' value='set Panel SR 200;toggle Panel LOAD' %} -Step 2: Deposit 012737 at ADDR 200: +Step 2: Deposit 012737 at ADDRESS 200. + {% include machine-command.html type='clickOnce' label='DEPOSIT 012737' machine='test1170' command='script' value='set Panel SR 012737;toggle Panel DEP' %} -Step 3: Deposit 000400 at ADDR 202: +Step 3: Deposit 000400 at ADDRESS 202. + {% include machine-command.html type='clickOnce' label='DEPOSIT 000400' machine='test1170' command='script' value='set Panel SR 000400;toggle Panel DEP' %} -Step 4: Deposit 177572 at ADDR 204: +Step 4: Deposit 177572 at ADDRESS 204. + {% include machine-command.html type='clickOnce' label='DEPOSIT 177572' machine='test1170' command='script' value='set Panel SR 177572;toggle Panel DEP' %} -Step 5: Deposit 012737 at ADDR 206: +Step 5: Deposit 012737 at ADDRESS 206. + {% include machine-command.html type='clickOnce' label='DEPOSIT 012737' machine='test1170' command='script' value='set Panel SR 012737;toggle Panel DEP' %} -Step 6: Deposit 070707 at ADDR 210: +Step 6: Deposit 070707 at ADDRESS 210. + {% include machine-command.html type='clickOnce' label='DEPOSIT 070707' machine='test1170' command='script' value='set Panel SR 070707;toggle Panel DEP' %} -Step 7: Deposit 000200 at ADDR 212: +Step 7: Deposit 000200 at ADDRESS 212. + {% include machine-command.html type='clickOnce' label='DEPOSIT 000200' machine='test1170' command='script' value='set Panel SR 000200;toggle Panel DEP' %} -Step 8: Deposit 000000 at ADDR 214: +Step 8: Deposit 000000 at ADDRESS 214. + {% include machine-command.html type='clickOnce' label='DEPOSIT 000000' machine='test1170' command='script' value='set Panel SR 000000;toggle Panel DEP' %} -Step 9: Load ADDR register with 300: +Step 9: Load ADDRESS register with 300. + {% include machine-command.html type='clickOnce' label='LOAD 300' machine='test1170' command='script' value='set Panel SR 300;toggle Panel LOAD' %} -Step 10: Deposit 300 at ADDR 300: +Step 10: Deposit 300 at ADDRESS 300. + {% include machine-command.html type='clickOnce' label='DEPOSIT 300' machine='test1170' command='script' value='toggle Panel DEP' %} -Step 11: Load ADDR register with 17772300: +Step 11: Load ADDRESS register with 17772300. + {% include machine-command.html type='clickOnce' label='LOAD 17772300' machine='test1170' command='script' value='set Panel SR 17772300;toggle Panel LOAD' %} -Step 12: Deposit 077406 at ADDR 17772300: +Step 12: Deposit 077406 at ADDRESS 17772300. + {% include machine-command.html type='clickOnce' label='DEPOSIT 077406' machine='test1170' command='script' value='set Panel SR 077406;toggle Panel DEP' %} -Step 13: Load ADDR register with 17772340: +Step 13: Load ADDRESS register with 17772340. + {% include machine-command.html type='clickOnce' label='LOAD 17772340' machine='test1170' command='script' value='set Panel SR 17772340;toggle Panel LOAD' %} -Step 14: Deposit 000001 at ADDR 17772340: +Step 14: Deposit 000001 at ADDRESS 17772340. + {% include machine-command.html type='clickOnce' label='DEPOSIT 000001' machine='test1170' command='script' value='set Panel SR 000001;toggle Panel DEP' %} -Step 15: Load ADDR register with 200: +Step 15: Load ADDRESS register with 200. + {% include machine-command.html type='clickOnce' label='LOAD 200' machine='test1170' command='script' value='set Panel SR 200;toggle Panel LOAD' %} -Step 16: Set ENABLE and toggle START: +Step 16: Set ENABLE and toggle START. + {% include machine-command.html type='clickOnce' label='START' machine='test1170' command='script' value='set Panel ENABLE 1; toggle Panel START' %} -Step 17: Load ADDR register with 300: +Step 17: Load ADDRESS register with 300. + {% include machine-command.html type='clickOnce' label='LOAD 300' machine='test1170' command='script' value='set Panel SR 300;toggle Panel LOAD' %} -Step 18: Examine ADDR 300: +Step 18: Examine ADDRESS 300. + {% include machine-command.html type='clickOnce' label='EXAM' machine='test1170' command='script' value='toggle Panel EXAM' %} Alternatively, with the PDPjs Debugger, the above "toggle-in" is easily entered with the following commands (the