PDP-11/45 Control Panels
The following Control Panel configurations are available:
- PDP-11/45 Front Panel (with Debugger)
Use this PDP-11/45 to see the PDP-11/45 Front Panel in action.
Front Panel Basics
From the PDP-11/45 Handbook (1973), Chapter 8, p. 195:
THE SYSTEM OPERATOR'S CONSOLE
The PDP-11/45 System Operator's Console is designed for convenient system control. A complete set of function switches and display indicators provide comprehensive status monitoring and control facilities.
8.1 CONSOLE ELEMENTS
The PDP-11/45 System Operator's Console provides the following facilities:
- A System Key Switch (OFF/ON/LOCK)
- A bank of 7 indicator lights, indicating the following Central Processor states: RUN, PAUSE, MASTER(UNIBUS), USER, SUPERVISOR, KERNEL, DATA.
- An 18-bit Address Register display
- An Addressing Error indicator light (ADRS ERR)
- A 16-bit Data Register display
- An 18-bit Switch Register
- Control knobs a. Address Display Select
- USER I VIRTUAL
- USER D VIRTUAL
- SUPERVISOR I VIRTUAL
- SUPERVISOR O VIRTUAL
- KERNEL I VIRTUAL
- KERNEL O VIRTUAL
- PROGRAM PHYSICAL
- CONSOLE PHYSICAL b. Data Display Select
- DATA PATHS
- BUS REGISTER
- FPP ADRS.CPU ADRS
- DISPLAY REGISTER
- Control Switches a. LOAD ADRS (Load Address) b. EXAM (Examine) c. REG EXAM (Register Examine) d. CONT (Continue) e. ENABLE/HALT f. S-INST/S-BUS CYCLE (Single Instruction/Single Bus Cycle) g. START h. DEPOSIT i. REG DEPOSIT
The PDPjs Front Panel replicates most (but not all) the features of a real PDP-11/45 Console. The switches, which PDPjs displays as green to make them stand out from the rest of the traditional pink-and-magenta controls, are summarized below.
0..21
Switches 0 to 21 control bits 0 to 21 of the SWITCH register. The UP position represents a 1, and the DOWN position represents a 0. Once all the bits have been set, you can choose to load the contents of the SWITCH register into the ADDRESS register (as displayed by the top row of LEDs), or directly into the memory location referenced by the ADDRESS register (where it will become the DATA displayed by the second row of LEDs).
The SWITCH, ADDRESS, and DATA (aka DISPLAY) registers are all internal to the Front Panel hardware, and should not be confused with CPU registers.
TEST
This is a momentary switch that is normally in the DOWN position. When held in the UP position, it turns on all LEDs. This "lamp test" was more important in the days when the lights were produced by bulbs with filaments that could burn out, and if you didn't realize that a particular light was "burned out", you could mistake it for a zero.
While the TEST switch is more "cute" than useful on a virtual Front Panel, we have added one "innovation" to the switch: pressing it also returns all the SWITCH register switches (0-21) to their DOWN position.
LOAD [ADRS]
This is a momentary switch that is normally in the UP position. When pressed DOWN, it copies the SWITCH register to the ADDRESS register.
EXAM
This is a momentary switch that is normally in the UP position. When pressed DOWN, it reads the memory location referenced by the ADDRESS register and displays it in the DATA register. If pressed repeatedly, each repetition also automatically adds 2 to the ADDRESS register, making it easier to examine a series of words. Note that if the CPU registers are being examined (starting at address 177700), the ADDRESS register will advance by 1 instead of 2.
Another "innovation" unique to PDPjs: if the STEP switch is toggled from the UP to the DOWN position, repeated EXAM or DEP operations will decrease the ADDRESS register instead of increasing it.
DEP
This is a momentary switch that is normally in the DOWN position. When pressed UP, it writes the contents of the SWITCH register to the memory location referenced by the ADDRESS register, and displays the result in the DATA register. Like the EXAM switch, if DEP is pressed repeatedly, each repetition also automatically adds 2 to the ADDRESS register, making it easier to deposit the same value to a series of words.
CONT
This is a momentary switch that is normally in the UP position. When pressed DOWN, it will start the CPU if it's currently halted. If the CPU is already running, CONT has no effect. Also, if the ENABLE/HALT switch is in the DOWN (HALT) position, then the CPU will continue for only ONE instruction and then stop again.
ENABLE/HALT
This switch is a toggle that is normally in the UP (ENABLE) position. If it pressed DOWN while the CPU is running, the CPU will stop. Once the CPU is stopped, this switch has no effect, other than determining what CONT will do when pressed.
STEP
On a real PDP-11, this would select between cycle-stepping vs. instruction-stepping. Since PDPjs doesn't support cycle-stepping, this switch has no effect (except as described above when the EXAM or DEP switches are pressed repeatedly).
START
The START switch is similar to CONT, but it also performs the equivalent a RESET instruction before starting the CPU, so unless you're starting execution at the beginning of a program, using START instead of CONT to continue execution is probably not a good idea. Also, if the ENABLE/HALT switch is in the DOWN (HALT) position, START will still reset the machine but not execute anything.