--- layout: page title: PDP-11 Test Panels permalink: /devices/pdp11/panel/test/ --- PDP-11 Test Panels ------------------ * [Terminal Test Panel](terminal.xml) (with [Debugger](debugger/terminal.xml)) Toggle-Ins ---------- From the [PDP-11/70 Maintenance Service Guide](http://archive.pcjs.org/pubs/dec/pdp11/1170/PDP1170_Maintenance_Service_Guide_Apr88.pdf), Chapter 4: There are several useful toggle-ins that are probably not very well known. They are as follows: Memory Management Use the following toggle-in to verify the correct operation of Memory Management Relocation. 200/012737 MOV #400,@#177572 (load maint. bit in MMRO) 202/000400 204/177572 206/012737 MOV #070707,@#200 (move 070707 to virtual 200) 210/070707 212/000200 214/000000 HLT 300/000300 Preset loc 300 to 300 17772300/077406 Set Kernal I PDR 0 to R/W 4K page 17772340/000001 Set Kernal I PAR 0 to (Base address 100) Load Address 200 Start Display = 000216 (Halt@214) Load Address 300 Exam Display = 070707 ... Relocation works Unibus Map Checkout Use the following console operating procedure to verify the correct operation of the Unibus Map. Load Address 500 Deposit 125252 Known Data Load Address 17000500 Deposit 125252 Data Path Ok Load Address 17000700 Deposit 070707 Known Data Load Address 17770202 Map register 0 Hi Deposit 000000 Relocation constant Load Address 17770200 Map register 0 Lo Deposit 000200 Relocation constant Load Address 17772516 MMR3 Deposit 000040 Enable map Load address 17000500 Relocates to 700 Examine 070707 ... Relocated ok