Added support for "clickOnce" script controls
This commit is contained in:
parent
54a7fb5119
commit
d190bc0c9c
7 changed files with 136 additions and 29 deletions
|
|
@ -6,6 +6,7 @@ machines:
|
|||
- id: test1170
|
||||
type: pdp11
|
||||
debugger: true
|
||||
sticky: top
|
||||
---
|
||||
|
||||
{% include machine.html id="test1170" %}
|
||||
|
|
@ -46,8 +47,62 @@ Debugger commands described below to load and execute these "toggle-ins".
|
|||
Load Address 300
|
||||
Exam Display = 070707 ... Relocation works
|
||||
|
||||
With the PDPjs Debugger, the above "toggle-in" is easily entered with the following commands (the semicolons are optional;
|
||||
they just make it easier to paste an entire set of commands into the Debugger at once):
|
||||
Step 1: Load ADDR register with 200:
|
||||
{% include machine-command.html type='clickOnce' label='LOAD 200' machine='test1170' command='script' value='set Panel SR 200;toggle Panel LOAD' %}
|
||||
|
||||
Step 2: Deposit 012737 at ADDR 200:
|
||||
{% include machine-command.html type='clickOnce' label='DEPOSIT 012737' machine='test1170' command='script' value='set Panel SR 012737;toggle Panel DEP' %}
|
||||
|
||||
Step 3: Deposit 000400 at ADDR 202:
|
||||
{% include machine-command.html type='clickOnce' label='DEPOSIT 000400' machine='test1170' command='script' value='set Panel SR 000400;toggle Panel DEP' %}
|
||||
|
||||
Step 4: Deposit 177572 at ADDR 204:
|
||||
{% include machine-command.html type='clickOnce' label='DEPOSIT 177572' machine='test1170' command='script' value='set Panel SR 177572;toggle Panel DEP' %}
|
||||
|
||||
Step 5: Deposit 012737 at ADDR 206:
|
||||
{% include machine-command.html type='clickOnce' label='DEPOSIT 012737' machine='test1170' command='script' value='set Panel SR 012737;toggle Panel DEP' %}
|
||||
|
||||
Step 6: Deposit 070707 at ADDR 210:
|
||||
{% include machine-command.html type='clickOnce' label='DEPOSIT 070707' machine='test1170' command='script' value='set Panel SR 070707;toggle Panel DEP' %}
|
||||
|
||||
Step 7: Deposit 000200 at ADDR 212:
|
||||
{% include machine-command.html type='clickOnce' label='DEPOSIT 000200' machine='test1170' command='script' value='set Panel SR 000200;toggle Panel DEP' %}
|
||||
|
||||
Step 8: Deposit 000000 at ADDR 214:
|
||||
{% include machine-command.html type='clickOnce' label='DEPOSIT 000000' machine='test1170' command='script' value='set Panel SR 000000;toggle Panel DEP' %}
|
||||
|
||||
Step 9: Load ADDR register with 300:
|
||||
{% include machine-command.html type='clickOnce' label='LOAD 300' machine='test1170' command='script' value='set Panel SR 300;toggle Panel LOAD' %}
|
||||
|
||||
Step 10: Deposit 300 at ADDR 300:
|
||||
{% include machine-command.html type='clickOnce' label='DEPOSIT 300' machine='test1170' command='script' value='toggle Panel DEP' %}
|
||||
|
||||
Step 11: Load ADDR register with 17772300:
|
||||
{% include machine-command.html type='clickOnce' label='LOAD 17772300' machine='test1170' command='script' value='set Panel SR 17772300;toggle Panel LOAD' %}
|
||||
|
||||
Step 12: Deposit 077406 at ADDR 17772300:
|
||||
{% include machine-command.html type='clickOnce' label='DEPOSIT 077406' machine='test1170' command='script' value='set Panel SR 077406;toggle Panel DEP' %}
|
||||
|
||||
Step 13: Load ADDR register with 17772340:
|
||||
{% include machine-command.html type='clickOnce' label='LOAD 17772340' machine='test1170' command='script' value='set Panel SR 17772340;toggle Panel LOAD' %}
|
||||
|
||||
Step 14: Deposit 000001 at ADDR 17772340:
|
||||
{% include machine-command.html type='clickOnce' label='DEPOSIT 000001' machine='test1170' command='script' value='set Panel SR 000001;toggle Panel DEP' %}
|
||||
|
||||
Step 15: Load ADDR register with 200:
|
||||
{% include machine-command.html type='clickOnce' label='LOAD 200' machine='test1170' command='script' value='set Panel SR 200;toggle Panel LOAD' %}
|
||||
|
||||
Step 16: Set ENABLE and toggle START:
|
||||
{% include machine-command.html type='clickOnce' label='START' machine='test1170' command='script' value='set Panel ENABLE 1; toggle Panel START' %}
|
||||
|
||||
Step 17: Load ADDR register with 300:
|
||||
{% include machine-command.html type='clickOnce' label='LOAD 300' machine='test1170' command='script' value='set Panel SR 300;toggle Panel LOAD' %}
|
||||
|
||||
Step 18: Examine ADDR 300:
|
||||
{% include machine-command.html type='clickOnce' label='EXAM' machine='test1170' command='script' value='toggle Panel EXAM' %}
|
||||
|
||||
Alternatively, with the PDPjs Debugger, the above "toggle-in" is easily entered with the following commands (the
|
||||
semicolons are optional; they just make it easier to paste an entire set of commands into the Debugger at once):
|
||||
|
||||
e 200 012737 000400 177572 012737 070707 000200 000000;
|
||||
e 300 000300;
|
||||
|
|
|
|||
Loading…
Reference in a new issue