@ -1,296 +0,0 @@
|
|||
Executing Real Mode Programs in Protected Mode
|
||||
---
|
||||
|
||||
An iAPX 86/88 program using real mode addressing can be executed in protected mode with full protection between
|
||||
it and other programs. All segment register semantics of iAPX 86 real mode can be emulated. The address space
|
||||
of the real mode program can also be limited to less than 1 megabyte and be relocated anywhere in the 16 Megabyte
|
||||
physical address space. The following sections describe several aspects of this emulation.
|
||||
|
||||
### Address space relocation and control ###
|
||||
|
||||
iAPX 86 real mode emulation requires any segment register load instruction cause a protection exception.
|
||||
An error code with bits 1-0 being zero and bits 15-2 being non-zero identify a segment register load exception.
|
||||
Such exceptions are restartable. All instructions that do not load a segment register run at full iAPX 286
|
||||
speed and with full access checks.
|
||||
|
||||
The exception handler must interpret the segment register load instruction to place the iAPX 86 paragraph ID
|
||||
and the associated protected descriptor into the [LOADALL](../loadall/) memory area. [LOADALL](../loadall/) then
|
||||
loads the segment register with the value used by the interrupted instruction, points the descriptor cache entry
|
||||
at the protected physical memory region, and restores the other segment registers.
|
||||
|
||||
Most segment load instructions will cause exception 13 if all LDT and GDT entries are marked with a privilege
|
||||
level less than the CPL of the emulated program. The CPL of the emulated program is defined by the DPL fields
|
||||
of the CS and SS descriptor caches.
|
||||
|
||||
Segment register loads using a selector value of 0000H to 0003H do not cause an exception on loading the
|
||||
segment register. Instead, any memory reference using the segment register will cause exception 13 with an
|
||||
error code of 0. No memory reference will occur. This case can be identified by checking whether DS or ES
|
||||
contain a value of 0-3. These exceptions are also restartable.
|
||||
|
||||
Limits can be enforced on the size of the emulated iAPX 86 address space. An iAPX 86 paragraph ID that is outside
|
||||
the defined memory area can be loaded, but the segment register can be marked invalid for memory addressing. [LOADALL](../loadall/)
|
||||
can be used to load the iAPX 86 paragraph ID into the segment register, but the descriptor cache entry is marked
|
||||
invalid. The paragraph ID can still be read without causing a protection exception.
|
||||
|
||||
If a selector value is loaded whose segment overruns the end of the defined physical memory area, the limit field
|
||||
can be set less than 65535 to prevent accesses outside the defined memory area with that segment register.
|
||||
|
||||
The emulated iAPX 86/88 address space can be relocated anywhere in the 16 Mbyte iAPX 286 physical address space by
|
||||
adding a 24-bit relocation factor to the 20-bit iAPX 86/88 physical address value associated with the iAPX 86
|
||||
paragraph ID.
|
||||
|
||||
### iAPX 86/88 Interrupt Table Simulation ###
|
||||
|
||||
The [LOADALL](../loadall/) instruction allows a protected mode 80286 to provide a simulated iAPX 86/88 interrupt
|
||||
table to iAPX 86/88 programs. The protected mode iAPX 286 interrupt table is different from iAPX 86/88 since it must
|
||||
contain more information and be protected from improper use. The protected mode interrupt table cannot be
|
||||
addressed by the same selector-offset pairs used in iAPX 86 real address mode.
|
||||
|
||||
The iAPX 86/88 interrupt table is simulated by having all INT instructions cause a protection exception.
|
||||
Setting the DPL of all IDT gate entries to less than the CPL of the emulated program will cause exception 13
|
||||
for all INT instructions. The error code will indicate an IDT vector with the EXT bit cleared. External
|
||||
interrupts and program exceptions will continue to use the protected IDT.
|
||||
|
||||
The iAPX 86/88 INT instruction can be simulated by the exception 13 handler. For INT instructions, it looks
|
||||
into the iAPX 86 interrupt vector table for the vector associated with the interrupt vector in the error code.
|
||||
After simulating the machine state save, the iAPX 86/88 program is restarted at the interrupt vector address.
|
||||
|
||||
Interrupt handlers for external interrupts can pass control to an iAPX 86 real mode program. Each external
|
||||
interrupt handler for an iAPX 86 interrupt must determine if the interrupt is for a real mode program; if so,
|
||||
then it emulates a real mode interrupt the same way as for the INT instruction.
|
||||
|
||||
### Allowing writes into a code segment ###
|
||||
|
||||
Code segment writes are possible by using writable data segment descriptors for the CS cache entry.
|
||||
Normally the code segment is write protected. If the code segment descriptor is always marked writable,
|
||||
then writes using the CS prefix will work correctly.
|
||||
|
||||
### Allowing temporaries to be placed into segment registers ###
|
||||
|
||||
A temporary value which does not correspond to a valid segment causes exception 13. It is possible to place
|
||||
that value into the program visible segment register, but mark the descriptor cache entry invalid. The invalid
|
||||
descriptor lets the program reference the numeric value stored in the segment register value, (i.e. MOV AX,ES)
|
||||
but prevents any memory reference instruction from using the segment register to address memory (i.e. MOV AX,ES:[BX]).
|
||||
|
||||
This feature requires an error handler to know that exception 13 with an error code which is an invalid segment
|
||||
selector value indicates a potential temporary value problem. The exception handler must simulate the segment load
|
||||
instruction to place the error code into the appropriate segment register and use [LOADALL](../loadall/) to mark the descriptor
|
||||
cache entry invalid. The program may then be resumed after the segment load instruction.
|
||||
|
||||
### Simulating I/O ###
|
||||
|
||||
All I/O instructions of the iAPX 86 program can be simulated. When the IOPL (I/O privilege level) is less than
|
||||
the CPL of the simulated iAPX 86 program, exception 13 will occur, with an error code of 0, on IN, OUT, STI, CLI,
|
||||
and LOCK instructions. The exception handler can identify these instructions and emulate their actions. The
|
||||
iAPX 86 program can then be restarted.
|
||||
|
||||
The LOCK instruction prefix causes exception 13 when CPL is greater than IOPL. For most systems, the LOCK prefix
|
||||
could be ignored. Restarting the program after the LOCK prefix would be acceptable. In special cases, the LOCKED
|
||||
instruction may need to be run with a lower CPL.
|
||||
|
||||
### Mixing emulated real mode software with native protected mode software ###
|
||||
|
||||
A system which emulates a real mode program may also run protected mode software. If the GDT and IDT has all
|
||||
entries marked level 2 or less, the emulated program cannot use them if it runs at level 3. The emulated program
|
||||
can have a task state segment associated with it. An LDT may be present if all entries are marked level 2 or less.
|
||||
Normal protected mode tasks may use an LOT with entries at privilege level 3.
|
||||
|
||||
Interrupt handlers may use either task or interrupt/trap gates. All interrupt handlers using trap/interrupt
|
||||
gates must execute at privilege level 2 or less. Interrupts that use task gates may run at any privilege level.
|
||||
|
||||
The register save operation of the task switch or interrupt handler will work without exceptions. The iAPX 86
|
||||
paragraph IDs in the segment registers can be read without a protection exception. The segment registers can be
|
||||
reloaded with protected selectors without a protection exception. Interrupting from a emulated iAPX 86 program
|
||||
does not affect interrupt latency.
|
||||
|
||||
Returning from an interrupt requires some checks. The return from the interrupt handler must check whether an
|
||||
iAPX 86 real mode program had been executing. If so, the return sequence must use the [LOADALL](../loadall/) instruction to reload
|
||||
all the registers rather than the normal IRET instruction.
|
||||
|
||||
Depending on the iAPX 86 paragraph IDs used, the IRET instruction might not cause a protection exception on
|
||||
returning to an emulated iAPX 86 program. The CS value of an interrupted iAPX 86 program saved on the stack or
|
||||
in the TSS does not correctly identify the privilege level, normally 3, of the emulated iAPX 86 real mode program.
|
||||
The privilege level of the interrupted program is determined by the RPL fields of the saved CS and SS selectors.
|
||||
If these values are the same and refer to a visible code segment, the CPU could attempt to execute the protected
|
||||
code segment at an incorrect address.
|
||||
|
||||
The interrupt handler should test whether an emulated iAPX 86 program was executing. An interrupted protected mode
|
||||
program can be restarted in the normal manner while an emulated program requires [LOADALL](../loadall/).
|
||||
|
||||
### Emulating an 8087 with the 80287 ###
|
||||
|
||||
The instruction and data addresses saved in the protected mode 80287 environment area are in a different format
|
||||
than from the 8087. In real mode, the 80287 environment is in the same format as the 8087. In protected mode,
|
||||
the 80287 environment is changed to store 32-bit virtual pointers rather than 20-bit iAPX 86/88 physical addresses.
|
||||
|
||||
The 80287 can be used by both normal protected mode programs and emulated iAPX 86/88 real mode programs. The 80287
|
||||
operates in either real mode or protected mode. The FSETPM instruction must be executed before starting a normal
|
||||
protected mode program if the 80287 was in real mode. The 80287 must be reset, via the RESET pin, to reenter real
|
||||
mode for an emulated iAPX 86/88 program after being used by a normal protected mode program. External hardware could
|
||||
reset the part to reenter real-mode. The TS bit of the MSW can be used to monitor for the first ESCAPE instruction
|
||||
executed in a program. The exception 7 handler can then determine what mode of operation is required in the 80287.
|
||||
|
||||
The 20-bit physical addresses kept by the 80287 for the instruction and data pointers will reflect the paragraph ID
|
||||
in the program visible segment register and offset used by the ESC instruction to address memory. The descriptor
|
||||
cache base and limit loaded by [LOADALL](../loadall/) is used to generate physical memory addresses for data transfers.
|
||||
|
||||
The WAIT instructions required by the 8087 before ESC instructions can be safely executed by the 80287.
|
||||
|
||||
Discrepancies from an iAPX 86/88 Using Emulation
|
||||
---
|
||||
|
||||
An 80286 cannot exactly emulate an 8086/88 in all possible cases. Most differences are due to the extra protection
|
||||
checks made in the 80286 which are not made in the 8086/88. The discrepancies listed here are minor enough that very
|
||||
few programs will be affected.
|
||||
|
||||
1. The PUSH SP instruction pushes a different value on the iAPX 286 than on the iAPX 86,88,186. The value pushed
|
||||
onto the stack by the 80286 is the value of SP before the push instruction executes. The value pushed onto the
|
||||
stack by the 8086/88/186 is the SP value after the push instruction executes.
|
||||
|
||||
2. Shifts and rotates on the iAPX 286 mask the count to 5 bits. The iAPX 86/88 allows all 8 bits to be used.
|
||||
The iAPX 186/188 also masks the shift count to 5 bits.
|
||||
|
||||
3. Segment wrap-around is not allowed on the 80286. Segment limit violations are not restartable in general on the
|
||||
80286. Programs that rely on reading some special value when referencing non-existent memory may not be correctly
|
||||
run.
|
||||
|
||||
Exceptions 9, 12, or 13 occur during attempts to wrap-around a segment depending on the location and type of
|
||||
operand involved. All exception 12 cases can be emulated and the program restarted. Exception 13 or 12 that
|
||||
occurs for an ESC instruction occurs before the 80286 or 80287 execute the instruction, and are therefore
|
||||
restartable. Exception 9 cannot be restarted.
|
||||
|
||||
Most simple load and store instructions that violate a segment limit are restartable. The current case that
|
||||
cannot be restarted in general is any floating point operand reference where the second or subsequent word
|
||||
exceeded a segment limit. The exception 9 handler __must__ execute FNINIT before __any__ other WAIT or ESC
|
||||
instruction. The internal status of the 80287 cannot be read until it is forced idle by FNINIT. The FNINIT
|
||||
instruction will mark all floating point data registers as empty, set top of stack to 0, and mask all errors.
|
||||
The numeric instruction and data addresses stored in the 80287 will correctly point at the failing instruction.
|
||||
If the 80286 program interrupted by the math address error is not the program that executed the failed ESC
|
||||
instruction, then that program can be restarted.
|
||||
|
||||
4. Memory address space wrap-around is not directly supported. The iAPX 86/88 allow wrap around from the top of
|
||||
the 1 megabyte address space into the bottom of the 1 megabyte address space (i.e. address FC00:4000 is same
|
||||
as 0000:0000). To emulate instructions that address memory with such wrap-around, requires the segment register
|
||||
limit be set to cause a protection exception for addresses beyond simulated physical address 0FFFFFH, or
|
||||
addresses below 00000H using an expand down segment, and software emulation of the instruction to address memory
|
||||
at the bottom of the address space.
|
||||
|
||||
5. An 8086/88/186 program will require different amounts of time to execute instructions on the 80286. Most
|
||||
instructions will run faster on the 80286. Instructions which do not modify a segment register, and do not
|
||||
use a segment register with a zero in it will run faster on the 80286. Instructions that first access memory
|
||||
with a segment register containing a zero will run slower on the 80286. Instructions that load a segment register
|
||||
with a non-zero selector value will run slower on the 80286.
|
||||
|
||||
6. The iAPX 286 and iAPX 186 can generate the most negative number as a quotient for the IDIV instruction.
|
||||
The iAPX 86/88 will generate the divide error exception instead.
|
||||
|
||||
7. The iAPX 286 divide error return address will point at the divide instruction including prefixes. The registers
|
||||
will appear as if the instruction had not executed. The iAPX 86/88/186/188 return address will point after the
|
||||
divide instruction and the DX:AX or AH:AL registers may have been changed.
|
||||
|
||||
8. The numeric instruction address stored in the 80287 includes all leading prefixes before the ESC opcode.
|
||||
The 8087 numeric instruction address always points at the ESC opcode.
|
||||
|
||||
9. An iAPX 286/20 system does not require an interrupt controller for the ERROR signal. iAPX 86/20 systems use an
|
||||
interrupt controller to prioritize simultaneous interrupts and mask errors from the 8087 if servicing them must
|
||||
be delayed.
|
||||
|
||||
If the same interrupt controller is provided as in the iAPX 86 system, the input used for the 8087 ERROR signal
|
||||
can be grounded. Instructions that control that input of the interrupt controller become NOPs. Watch out for
|
||||
non-specific EOI instructions inside an 8087 error handler which may affect other interrupt inputs.
|
||||
|
||||
80287 errors do not normally affect an interrupt handler. As long as any program does not execute WAIT or ESC
|
||||
instructions, it cannot be interrupted by the 80287.
|
||||
|
||||
If a different interrupt system is used in the iAPX 286 system than in the iAPX 86 system, any I/O instructions
|
||||
to the interrupt controller may have to be emulated.
|
||||
|
||||
10. Numeric error interrupts use interrupt vector 16. Since an external interrupt controller may be used in
|
||||
iAPX 86,88,186 systems, another interrupt vector may have been used for numeric interrupts.
|
||||
|
||||
11. Do not perform port I/O to ports 00F8H to 00FFH. The 80287 may not operate properly if this is allowed.
|
||||
These I/O locations are reserved by Intel.
|
||||
|
||||
12. The interrupt enable bit of the flag word may not change when a POPF or IRET instruction attempts to change it.
|
||||
The IOPL field of the flag word controls whether IF can be changed. Subsequent PUSHF and INT instructions will
|
||||
save a value of IF which differs from the value in an 8086/8088 program.
|
||||
|
||||
13. If STI and CLI are emulated as NOPs then they will fail to change IF. Subsequent PUSHF and INT instructions
|
||||
will save a value of IF which differs from the value in an 8086/8088 program.
|
||||
|
||||
14. The flag word has two new fields: IOPL and NT. IOPL can not change except at level 0, but NT can be changed by
|
||||
IRET and POPF instructions. The IRET instruction attempts a task switch when NT is set. The back link field of
|
||||
the current TSS should have a 0 in it to cause exception 13, with an error code of 0, if the iAPX 86 program
|
||||
attempts an IRET after setting NT. The exception 13 handler may then simulate an iAPX 86 !RET operation.
|
||||
|
||||
15. The iAPX 86 address space may be limited. Programs may use some form of memory space scanner to see how much
|
||||
memory is available. Accesses to illegal locations are expected. The program emulator must decide what to do
|
||||
about illegal accesses.
|
||||
|
||||
16. The 80286 defines new instructions for undefined opcodes in the 8086/88. An 8086/88 program with an unknown
|
||||
bug in it that executes these undefined opcodes will work differently on an 80286.
|
||||
|
||||
17. Programs with self-modifying code may work differently on an 80286. The 80286 prefetcher can fetch more bytes
|
||||
ahead of the current instruction than the 8086 or 8088. A program that modifies an instruction that has already
|
||||
been prefetched will not see the changed instruction. Any program which jumps after modifying an instruction
|
||||
before executing it will correctly execute the modified instruction.
|
||||
|
||||
18. Regions of the emulated iAPX 86,88,186 address space can not be write protected. The XCHG, ADC, SBB, RCL, and
|
||||
RCR instructions are not restartable if their memory-based operand is in a write-protected segment.
|
||||
|
||||
Extending the Address Space of Current iAPX 86 Software
|
||||
---
|
||||
|
||||
Current iAPX 86 real mode programs can use the extended address space of the iAPX 286 in a limited manner.
|
||||
To address the extended memory, [LOADALL](../loadall/) must be used to load the descriptor cache with an base address beyond
|
||||
the normal 1 Mbyte address range. That segment register must not be changed by software, else the segment register
|
||||
will point back into the 1 Mbyte address space.
|
||||
|
||||
Two types of systems are examined: accessing a single large database in a limited manner, or splitting software
|
||||
into normal and extended areas. The first is the easiest to implement, while the second is more general.
|
||||
|
||||
Access to a large data area outside the 1 Mbyte address space could be provided by a subroutine. The subroutine
|
||||
scans the large data structure to locate the necessary item, then copy all data between the normal address space
|
||||
and the extended address space.
|
||||
|
||||
Interrupts must be disabled while the subroutine uses segment registers that have been set by [LOADALL](../loadall/). The reload
|
||||
of segment registers inside an interrupt routine would change the actual physical address from that loaded by [LOADALL](../loadall/)
|
||||
before the interrupt. After all accesses in the extended area are done, interrupts may be enabled.
|
||||
|
||||
Returning the address of an extended data structure requires passing data through a segment register. For example,
|
||||
the ES register could have been changed by [LOADALL](../loadall/) to point at a data area outside the bottom megabyte of physical
|
||||
memory. The subroutine must not reload ES while it runs. The value stored in ES is not important since it is not
|
||||
related to the physical address. Interrupts must not be allowed since the interrupt routine may reload ES.
|
||||
|
||||
A second technique uses special paragraph IDs (i.e. FFFFH) to signal that a piece of software is running in extended
|
||||
mode. All interrupt handlers in the system must look when they return to the interrupted program to see if any of the
|
||||
segment registers contain FFFFH. If so, then that segment register points at extended memory. [LOADALL](../loadall/) must be used
|
||||
to load all the registers and the segment base address used last. The [LOADALL](../loadall/) memory area should contain that value
|
||||
left there from the previous usage. Descriptors for the other segment registers with normal paragraph IDs must be
|
||||
constructed before executing [LOADALL](../loadall/).
|
||||
|
||||
A semaphore must be placed around software that writes into the [LOADALL](../loadall/) area such that once written into, the software
|
||||
can execute [LOADALL](../loadall/) without interruption.
|
||||
|
||||
Mixing Real Mode and Protected Mode
|
||||
---
|
||||
|
||||
The 80286 can alternate between real mode and protected mode. Some programs could be executed in real mode in the
|
||||
bottom megabyte of memory, while others execute in protected mode in the upper 15 Mbytes of memory. An external OR
|
||||
gate could RESET the 80286, independent of the rest of the system, to force it to enter real mode. A short routine
|
||||
at the power up address could redirect the software to the correct real mode program.
|
||||
|
||||
After executing the real mode program, [LOADALL](../loadall/) could then quickly restart the protected mode software. [LOADALL](../loadall/) can
|
||||
be used as a form of task switch from real mode to a protected mode task.
|
||||
|
||||
One operating system could service both the real and protected mode software. Any operating system call from the real
|
||||
mode program would cause a switch to protected mode. The protected mode software could then construct descriptors that
|
||||
refer to the same physical memory addresses used by the real mode paragraph IDs. After conversion, the operating system
|
||||
could then perform all work in protected mode.
|
||||
|
||||
Interrupts must be handled specially. Interrupt handlers for both real mode and protected mode must be present at all
|
||||
times. If an interrupt handler needs to access a data area, that data area must be addressable from both real and
|
||||
protected mode. The real mode interrupt table would be would be kept at location 000000H. The protected mode IDT could
|
||||
be anywhere. [LOADALL](../loadall/) will switch to the protected interrupt table.
|
||||
|
||||
[This information is from an undated 15-page Intel document titled "Undocumented iAPX 286 Test Instruction"]
|
||||
Loading…