Updated MACRO-10 diagnostic README files
This commit is contained in:
parent
cca8c9f090
commit
91ed20000c
2 changed files with 50 additions and 44 deletions
|
|
@ -7,8 +7,11 @@ permalink: /apps/pdp10/
|
|||
PDP-10 Software
|
||||
---------------
|
||||
|
||||
PCjs provides the following PDP-10 software:
|
||||
PCjs has archived the following DEC PDP-10 software:
|
||||
|
||||
- [DEC PDP-10 Diagnostics](diags/)
|
||||
|
||||
PCjs also includes a random collection of home-grown PDP-10 tests:
|
||||
|
||||
- [PDPjs PDP-10 Opcode Tests](tests/opcodes/)
|
||||
- [PDPjs MACRO-10 Mini-Assembler Tests](tests/macro10/)
|
||||
|
|
|
|||
|
|
@ -11,46 +11,8 @@ PCjs has archived selected KA10 diagnostic source files from the
|
|||
[PDP-10 KLAD Diagnostics Sources](http://pdp-10.trailing-edge.com/klad_sources/index.html) and turned them into
|
||||
stand-alone PDP-10 diagnostics, using the new PCjs [MACRO-10 Mini-Assembler](/modules/pdp10/lib/macro10.js).
|
||||
|
||||
Complete lists of supported [diagnostics](#list-of-ka10-diagnostics) and [reliability tests](#list-of-ka10-reliability-tests)
|
||||
are provided below.
|
||||
|
||||
I've also experimented with assembling these diagnostics from the original (unmodified) source files. For example,
|
||||
you can go to the [DAKAK Diagnostic](dakak/) page and try the following command:
|
||||
|
||||
a 'DAKAKT.MAC;../PARAM.KLM;../FIXED.KLM;DAKAKM.MAC;../UUOERR.KLM;../STOR.KLM'
|
||||
|
||||
and while the MACRO-10 assembly process works:
|
||||
|
||||
loading DAKAKT.MAC
|
||||
loading PARAM.KLM
|
||||
loading FIXED.KLM
|
||||
loading DAKAKM.MAC
|
||||
loading UUOERR.KLM
|
||||
loading STOR.KLM
|
||||
6301 words loaded at 000137-044630, start address 030000
|
||||
00=000000000000 01=000000000000 02=000000000000 03=000000000000
|
||||
04=000000000000 05=000000000000 06=000000000000 07=000000000000
|
||||
10=000000000000 11=000000000000 12=000000000000 13=000000000000
|
||||
14=000000000000 15=000000000000 16=000000000000 17=000000000000
|
||||
PC=030000 RA=00000000 EA=000000 PS=000000 OV=0 C0=0 C1=0 ND=0 PD=0
|
||||
030000: 254020 027776 JRST @27776
|
||||
|
||||
there are additional modules that must be loaded into the machine as well, which are not yet supported. So it's best
|
||||
to assemble the modified files that I've placed inside each diagnostic's folder. For the [DAKAK Diagnostic](dakak/),
|
||||
that's **DAKAK.MAC**:
|
||||
|
||||
>> a DAKAK.MAC
|
||||
loading DAKAK.MAC
|
||||
5849 words loaded at 000137-044133, start address 030621
|
||||
00=000000000000 01=000000000000 02=000000000000 03=000000000000
|
||||
04=000000000000 05=000000000000 06=000000000000 07=000000000000
|
||||
10=000000000000 11=000000000000 12=000000000000 13=000000000000
|
||||
14=000000000000 15=000000000000 16=000000000000 17=000000000000
|
||||
PC=030621 RA=00000000 EA=000000 PS=000000 OV=0 C0=0 C1=0 ND=0 PD=0
|
||||
030621: 254000 030622 JRST 30622
|
||||
|
||||
If the machine is able to run to the end of the diagnostic (which can be located by looking at the diagnostic's original
|
||||
MACRO-10 listing file) without stopping on an UUO opcode, then you can assume it passed.
|
||||
Lists of supported [diagnostics](#list-of-ka10-diagnostics) and [reliability tests](#list-of-ka10-reliability-tests)
|
||||
are provided below, as well as some [notes](#notes-on-ka10-diagnostics) on assembling the diagnostics.
|
||||
|
||||
List of KA10 Diagnostics
|
||||
------------------------
|
||||
|
|
@ -135,7 +97,7 @@ so far.
|
|||
- TESTS OF MULTIPY, INTERGER MULTIPLY, DIVIDE, INTERGER DIVIDE*
|
||||
- [KA10 Basic Instruction Diagnostic #12 (MAINDEC-10-DAKAL)](dakal/)
|
||||
- TESTS THE MULTIPY, INTERGER MULIPLY, DIVIDE AND INTERGER DIVIDE INSTRUCTIONS*
|
||||
- [KA10 Basic Instruction Diagnostic #13 (MAINDEC-10-DAKAL)](dakam/)
|
||||
- [KA10 Basic Instruction Diagnostic #13 (MAINDEC-10-DAKAM)](dakam/)
|
||||
- TESTS THE BYTE, BLOCK TRANSFER AND JFFO INSTRUCTIONS
|
||||
|
||||
*Gotta love those multipy, interger muliply, and interger divide tests! -JP
|
||||
|
|
@ -143,8 +105,49 @@ so far.
|
|||
List of KA10 Reliability Tests
|
||||
------------------------------
|
||||
|
||||
Like the diagnostics above, the following list of KA10 Reliability Tests are simple those tests that have been archived and tested
|
||||
with PDPjs so far.
|
||||
Like the diagnostics above, the following list of KA10 Reliability Tests are simple those tests that have been
|
||||
archived and tested with PDPjs so far.
|
||||
|
||||
- [KA10 Basic Instruction Reliability Test #1 (MAINDEC-10-DAKBA)](dakba/)
|
||||
- COMPARES, SKIPS, EXCHANGES, BOOLE, ROTATES, TESTS
|
||||
|
||||
Notes on KA10 Diagnostics
|
||||
-------------------------
|
||||
|
||||
It's possible to assemble some of the above diagnostics from the original (unmodified) source files. For example,
|
||||
you can go to the [DAKAK Diagnostic](dakak/) page and enter the following Debugger command:
|
||||
|
||||
a 'DAKAKT.MAC;../PARAM.KLM;../FIXED.KLM;DAKAKM.MAC;../UUOERR.KLM;../STOR.KLM'
|
||||
|
||||
However, while the MACRO-10 assembly process appears to work:
|
||||
|
||||
loading DAKAKT.MAC
|
||||
loading PARAM.KLM
|
||||
loading FIXED.KLM
|
||||
loading DAKAKM.MAC
|
||||
loading UUOERR.KLM
|
||||
loading STOR.KLM
|
||||
6301 words loaded at 000137-044630, start address 030000
|
||||
00=000000000000 01=000000000000 02=000000000000 03=000000000000
|
||||
04=000000000000 05=000000000000 06=000000000000 07=000000000000
|
||||
10=000000000000 11=000000000000 12=000000000000 13=000000000000
|
||||
14=000000000000 15=000000000000 16=000000000000 17=000000000000
|
||||
PC=030000 RA=00000000 EA=000000 PS=000000 OV=0 C0=0 C1=0 ND=0 PD=0
|
||||
030000: 254020 027776 JRST @27776
|
||||
|
||||
there are additional modules that must be loaded into the machine as well, which are not yet supported. So it's best
|
||||
to assemble the modified files that have been placed inside each diagnostic's folder. For the [DAKAK Diagnostic](dakak/),
|
||||
that's **DAKAK.MAC**:
|
||||
|
||||
>> a DAKAK.MAC
|
||||
loading DAKAK.MAC
|
||||
5849 words loaded at 000137-044133, start address 030621
|
||||
00=000000000000 01=000000000000 02=000000000000 03=000000000000
|
||||
04=000000000000 05=000000000000 06=000000000000 07=000000000000
|
||||
10=000000000000 11=000000000000 12=000000000000 13=000000000000
|
||||
14=000000000000 15=000000000000 16=000000000000 17=000000000000
|
||||
PC=030621 RA=00000000 EA=000000 PS=000000 OV=0 C0=0 C1=0 ND=0 PD=0
|
||||
030621: 254000 030622 JRST 30622
|
||||
|
||||
If the machine is able to run to the end of the diagnostic (which can be located by looking at the diagnostic's original
|
||||
MACRO-10 listing file) without stopping on an UUO opcode, then the diagnostic likely succeeded.
|
||||
|
|
|
|||
Loading…