Fixed the signed 8-bit calculation of all PDP-10 shift/rotate counts; diagnostic DAKAJ now passes
This commit is contained in:
parent
881da5b19c
commit
90ae3f1db8
6 changed files with 766 additions and 366 deletions
|
|
@ -81,3 +81,5 @@ PCjs has archived selected files from
|
|||
- TESTS OF PI, INTERRUPTS, LUUO'S, I/O
|
||||
- [KA10 Basic Instruction Diagnostic #9 (MAINDEC-10-DAKAI)](dakai/)
|
||||
- TESTS OF LOGICAL SHIFT, ROTATE, ARITHMETIC SHIFT; SINGLE AND COMBINED
|
||||
- [KA10 Basic Instruction Diagnostic #10 (MAINDEC-10-DAKAJ)](dakaj/)
|
||||
- TESTS OF LOGICAL SHIFT, ROTATE, ARITHMETIC SHIFT; SINGLE AND COMBINED
|
||||
|
|
|
|||
|
|
@ -44,11 +44,386 @@ DAKAJ.TXT
|
|||
---------
|
||||
|
||||
```
|
||||
MAINDEC-10-DAKAJ.TXT
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
IDENTIFICATION
|
||||
--------------
|
||||
|
||||
PRODUCT CODE: MAINDEC-10-DAKAJ-B-D
|
||||
|
||||
PRODUCT NAME: DECSYSTEM10 PDP-10 KA10 BASIC
|
||||
INSTRUCTION DIAGNOSTIC (10)
|
||||
|
||||
FUNCTION: SHIFT-ROTATE TEST (PART 2)
|
||||
|
||||
VERSION: 0.2
|
||||
|
||||
DATE RELEASED: JANUARY 1977
|
||||
|
||||
MAINTAINED BY: DIAGNOSTIC ENGINEERING GROUP
|
||||
|
||||
AUTHOR: JOHN R. KIRCHOFF
|
||||
|
||||
COPYRIGHT(C) 1976,1977
|
||||
DIGITAL EQUIPMENT CORPORATION
|
||||
MARLBORO, MASS. 01752
|
||||
|
||||
THIS SOFTWARE IS FURNISHED UNDER A LICENSE FOR USE ONLY
|
||||
ON A SINGLE COMPUTER SYSTEM AND MAY BE COPIED ONLY WITH
|
||||
THE INCLUSION OF THE ABOVE COPYRIGHT NOTICE. THIS SOFTWARE,
|
||||
OR ANY OTHER COPIES THEREOF, MAY NOT BE PROVIDED OR OTHERWISE
|
||||
MADE AVAILABLE TO ANY OTHER PERSON EXECPT FOR USE ON SUCH SYSTEM
|
||||
AND TO ONE WHO AGREES TO THESE LICENSE TERMS. TITLE TO AND
|
||||
OWNERSHIP OF THE SOFTWARE SHALL AT ALL TIMES REMAIN IN DEC.
|
||||
|
||||
THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT
|
||||
NOTICE AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL
|
||||
EQUIPMENT CORPORATION.
|
||||
|
||||
DEC ASSUMES NO RESPONSIBILITY FOR THE USE OR RELIABILITY OF ITS
|
||||
SOFTWARE ON EQUIPMENT WHICH IS NOT SUPPLIED BY DEC.
|
||||
|
||||
MAINDEC-10-DAKAJ.TXT
|
||||
PAGE 2
|
||||
|
||||
TABLE OF CONTENTS
|
||||
-----------------
|
||||
|
||||
1.0 ABSTRACT
|
||||
|
||||
2.0 REQUIREMENTS
|
||||
|
||||
2.1 EQUIPMENT
|
||||
|
||||
2.2 STORAGE
|
||||
|
||||
2.3 PRELIMINARY PROGRAMS
|
||||
|
||||
3.0 PROGRAM PROCEDURES
|
||||
|
||||
3.1 LOADING PROCEDURE
|
||||
|
||||
3.2 STARTING PROCEDURE
|
||||
|
||||
3.3 OPERATING PROCEDURE
|
||||
|
||||
4.0 DATA SWITCH FUNCTIONS
|
||||
|
||||
5.0 ERRORS
|
||||
|
||||
6.0 ITERATION COUNTER
|
||||
|
||||
7.0 CYCLE TIME
|
||||
|
||||
8.0 OPERATIONAL VARIATIONS
|
||||
|
||||
9.0 MISCELLANEOUS
|
||||
|
||||
10.0 LISTING
|
||||
|
||||
MAINDEC-10-DAKAJ.TXT
|
||||
PAGE 3
|
||||
|
||||
1.0 ABSTRACT
|
||||
|
||||
THIS PDP-10 KA10 BASIC INSTRUCTION DIAGNOSTIC IS THE
|
||||
TENTH IN A SERIES OF PDP-10 KA10 PROCESSOR DIAGNOSTICS.
|
||||
THE DIAGNOSTIC CONTINUES TESTING THE SHIFT
|
||||
AND ROTATE INSTRUCTIONS.
|
||||
|
||||
2.0 REQUIREMENTS
|
||||
|
||||
2.1 EQUIPMENT
|
||||
|
||||
A PDP-10 KA10 EQUIPPED WITH A MINIMUM OF 32K OF MEMORY
|
||||
|
||||
PAPER TAPE READER
|
||||
CONSOLE TELETYPE
|
||||
DECTAPE
|
||||
LINE PRINTER (OPTIONAL)
|
||||
|
||||
2.2 STORAGE
|
||||
|
||||
THE PROGRAM RUNS WITHIN 32K OF MEMORY.
|
||||
|
||||
2.3 PRELIMINARY PROGRAMS
|
||||
|
||||
PREVIOUS PROCESSOR DIAGNOSTICS
|
||||
|
||||
3.0 PROGRAM PROCEDURES
|
||||
|
||||
3.1 LOADING PROCEDURE
|
||||
|
||||
THIS DIAGNOSTIC REQUIRES THAT THE DECSYSTEM10 SUBROUTINE
|
||||
PROGRAM BE RESIDENT IN THE PDP-10.
|
||||
|
||||
PAPER TAPE - HARDWARE READ-IN (READER DEVICE CODE 104)
|
||||
DECTAPE - LOAD WITH DIAMON (DECTAPE DEVICE CODE 320)
|
||||
TIME SHARING - RUN UNDER DIAMON.
|
||||
|
||||
MAINDEC-10-DAKAJ.TXT
|
||||
PAGE 4
|
||||
|
||||
3.2 STARTING PROCEDURE
|
||||
|
||||
A. SELECT OPERATIONAL CONSOLE DATA SWITCH SETTINGS (REFER TO
|
||||
4.0 DATA SWITCH FUNCTIONS).
|
||||
|
||||
B. EXEC MODE
|
||||
|
||||
STAND-ALONE STARTING ADDRESS IS 30000.
|
||||
|
||||
C. USER MODE
|
||||
|
||||
RUN UNDER "DIAMON".
|
||||
IN USER MODE THE FOLLOWING QUESTIONS WILL BE ASKED TO
|
||||
SELECT THE OPERATIONAL SWITCHES:
|
||||
|
||||
TELETYPE SWITCH CONTROL ? 0,S,Y OR N (CR) -
|
||||
|
||||
IF THE OPERATOR TYPES "N", THE ACTUAL CONSOLE
|
||||
SWITCHES ARE USED.
|
||||
|
||||
IF THE OPERATOR TYPES "Y", THE FOLLOWING QUESTIONS
|
||||
ARE ASKED AND THE OPERATOR RESPONDS BY TYPING
|
||||
THE ANSWER AS SIX OCTAL DIGITS REPRESENTING
|
||||
THE DESIRED SWITCH SETTINGS.
|
||||
|
||||
SPECIFY LH SWITCHES IN OCTAL-
|
||||
|
||||
SPECIFY RH SWITCHES IN OCTAL-
|
||||
|
||||
IF THE OPERATOR TYPES "0", ZERO'S ARE USED FOR
|
||||
THE SWITCH SETTINGS.
|
||||
|
||||
IF THE OPERATOR TYPES "S", PREVIOUSLY SET SWITCHES
|
||||
ARE USED. THIS IS ONLY VALID UPON RESTARTING
|
||||
OF AN INTERRUPTED PROGRAM.
|
||||
|
||||
MAINDEC-10-DAKAJ.TXT
|
||||
PAGE 5
|
||||
|
||||
3.3 OPERATING PROCEDURE
|
||||
|
||||
A. TO THROUGHLY TEST ALL HARDWARE, ALL TEST CONTROL DATA
|
||||
SWITCHES SHOULD BE SET TO 0.
|
||||
|
||||
B. WHEN DEBUGGING HARDWARE, SET SWITCHES TO 0. ALLOW THE
|
||||
TELETYPE TO PRINT THE ERROR MESSAGES. THIS ALLOWS THE
|
||||
PROGRAM TO RUN A COMPLETE PASS AND THEN THE ERROR MESSAGES
|
||||
MAY BE CORRELATED TO QUICKLY DIAGNOSE THE FAILURE. IF A
|
||||
HARDWARE PROBLEM IS SUCH THAT THE ERROR MESSAGES, AFTER THE
|
||||
FIRST ONE, HAVE NO MEANING (FIRST ERROR CAUSES ALL FOLLOWING
|
||||
TESTS TO FAIL) SET THE LOOP ON ERROR SWITCH AND RESTART THE
|
||||
TEST FROM THE BEGINNING. THE FIRST FAILURE WILL THEN CAUSE
|
||||
THE PROGRAM TO ENTER A LOOP SUITABLE FOR SCOPING.
|
||||
|
||||
THE ERROR MESSAGE USED IN CONJUNCTION WITH THE LISTING AND
|
||||
SCOPING IF NECESSARY SHOULD ALLOW THE FAILING CONPONENT
|
||||
TO BE ISOLATED AND REPLACED AND/OR REPAIRED.
|
||||
|
||||
C. WHEN TAKING MARGINS, SET DATA SWITCHES 'NOPNT' AND 'DING'.
|
||||
THIS WILL INHIBIT PRINTOUT BUT WILL ALLOW THE TELETYPE
|
||||
BELL TO BE RUNG WHEN A ERROR OCCURS. IF THE MARGIN OBTAINED
|
||||
IS UNACCEPTABLE, THE OPERATOR MAY REVERT TO STANDARD SWITCH
|
||||
SETTINGS FOR DEBUGGING PURPOSES.
|
||||
|
||||
D. ERROR INFORMATION MAY BE OBTAINED QUICKLY BY PRINTING
|
||||
ERRORS ON THE LINE PRINTER.
|
||||
|
||||
E. IN THE EVENT OF A PRINT ROUTINE FAILURE THE 'NOPNT' SWITCH
|
||||
AND THE 'ERSTOP' SWITCH MAY BE SET TO INHIBIT PRINTOUT
|
||||
BUT HALT THE PROGRAM POINTING TO THE ERROR.
|
||||
|
||||
MAINDEC-10-DAKAJ.TXT
|
||||
PAGE 6
|
||||
|
||||
4.0 DATA SWITCH FUNCTIONS
|
||||
|
||||
SWITCH STATE FUNCTION
|
||||
------ ----- --------
|
||||
|
||||
0 ABORT 0 NORMAL OPERATION
|
||||
1 ABORT AT END OF PASS
|
||||
|
||||
1 RSTART NOT USED
|
||||
|
||||
2 TOTALS NOT USED
|
||||
|
||||
3 NOPNT 0 NORMAL TYPEOUT
|
||||
1 INHIBIT ALL PRINT/TYPEOUT
|
||||
(EXCEPT FORCED)
|
||||
|
||||
4 PNTLPT 0 NORMAL OUTPUT TO TTY
|
||||
1 PRINT ALL DATA ON LPT
|
||||
(LOGICAL DEVICE, USER MODE)
|
||||
|
||||
5 DING 0 NO FUNCTION
|
||||
1 RING TTY BELL ON ERROR
|
||||
|
||||
6 LOOPER 0 PROCEED TO NEXT TEST
|
||||
1 ENTER SCOPE LOOP ON TEST ERROR
|
||||
|
||||
7 ERSTOP 0 NO FUNCTION
|
||||
1 HALT ON TEST ERROR
|
||||
|
||||
8 PALERS 0 PRINT ONLY FIRST ERROR WHEN LOOPING
|
||||
1 PRINT ALL ERRORS, EVEN IF SAME ERROR
|
||||
|
||||
9 RELIAB NOT USED
|
||||
|
||||
10 TXTINH 0 PRINT FULL ERROR MESSAGES.
|
||||
1 INHIBIT COMMENT PORTION OF
|
||||
ERROR MESSAGES.
|
||||
|
||||
11 INHPAG 0 ALLOW PAGING AND TRAP ENABLE
|
||||
1 INHIBIT PAGING AND TRAPPING
|
||||
|
||||
12 MODDVC NOT USED
|
||||
|
||||
13 INHCSH NOT USED
|
||||
|
||||
MAINDEC-10-DAKAJ.TXT
|
||||
PAGE 7
|
||||
|
||||
5.0 ERRORS
|
||||
|
||||
ERRORS ARE PRINTED ON THE TTY OR LINE PRINTER. THE ERROR
|
||||
PRINTOUT CONTAINS THE TEST TITLE, THE PC OF THE FAILURE, ERROR
|
||||
NUMBER AND THE CONTENTS OF AN APPLICABLE AC.
|
||||
|
||||
THE PC VALUE IS USEFUL IN RELATING THE FAILURE TO THE LISTING.
|
||||
THE ERROR NUMBER IS PROVIDED SUCH THAT AN ERROR DICTIONARY MAY
|
||||
BE MADE AT SOME FUTURE DATE.
|
||||
|
||||
WHEN THE SCOPE LOOP MODE IS USED THE MI REGISTER WILL COUNT
|
||||
FOR EACH OCCURANCE OF AN ERROR. IF AN AUDIO INDICATION OF
|
||||
A CONTINUING ERROR IS DESIRED THE 'DING' SWITCH MAY BE SET.
|
||||
|
||||
6.0 ITERATION COUNTER
|
||||
|
||||
THE ITERATION COUNT OF THE PROGRAM IS DISPLAYED IN THE MEMORY
|
||||
INDICATORS (MI). THIS COUNT IS A DECREMENTING COUNT AND
|
||||
INITIALLY STARTS AT -1 IN STAND-ALONE OPERATION.
|
||||
|
||||
7.0 CYCLE TIME
|
||||
|
||||
THE CYCLE TIME OF THE PROGRAM IS IN THE MILLISECOND RANGE AND
|
||||
IS THEREFORE SUITABLE FOR TAKING MARGINS, VIBRATION TESTS,
|
||||
ETC.
|
||||
|
||||
MAINDEC-10-DAKAJ.TXT
|
||||
PAGE 8
|
||||
|
||||
8.0 OPERATIONAL VARIATIONS
|
||||
|
||||
A. DIAGNOSTIC MONITOR
|
||||
|
||||
THE PROGRAM IS USABLE WITH THE DIAGNOSTIC MONITOR TO PROVIDE
|
||||
RELIABILITY TESTS, ACCEPTANCE TESTS, AND/OR TO PROVIDE A
|
||||
QUICK METHOD OF ISOLATION OF A FAULT TO A PARTICULAR AREA
|
||||
OF THE PROCESSOR. CERTAIN PROCEDURES ARE USED WHEN THE
|
||||
PROGRAM IS USED IN THIS MANNER. THEY ARE:
|
||||
|
||||
1. THE DIAGNOSTIC MONITOR TRANSFERS CONTROL TO THE PROGRAM
|
||||
AND STARTS IT AT LOCATION 30002.
|
||||
|
||||
2. MONCTL - LOCATION 30043 IS USED AS THE DIAGNOSTIC MONITOR
|
||||
CONTROL WORD.
|
||||
LH = 0, STAND-ALONE OPERATION
|
||||
-1, RUNNING UNDER DIAGNOSTIC MONITOR
|
||||
|
||||
RH = RIGHT HALF OF CONSOLE SWITCHES IF UNDER
|
||||
DIAGNOSTIC MONITOR CONTROL.
|
||||
|
||||
B. USER MODE
|
||||
|
||||
TO OUTPUT THE PRINTED ERROR MESSAGES TO A USER SPECIFIED
|
||||
DEVICE IN USER MODE, ASSIGN THE DESIRED OUTPUT DEVICE TO
|
||||
DEVICE NAME 'DEV' AND SET SWITCH 'PNTLPT'. THE PHYSICAL
|
||||
DEVICE USED CAN BE ANY DEVICE THAT CAN ACCEPT ASCII OUTPUT
|
||||
FORMAT SUCH AS LPT, DSK, DTA, ETC. THE CORRESPONDING
|
||||
OUTPUT FILE IS 'DAKAJ.TMP'
|
||||
|
||||
EXAMPLE DEVICE ASSIGNMENT:
|
||||
|
||||
.ASSIGN DSK DEV
|
||||
|
||||
IN USER MODE THE PROGRAM WILL MAKE 1000(8) PASSES AND THEN
|
||||
RETURN TO DIAMON COMMAND MODE.
|
||||
|
||||
MAINDEC-10-DAKAJ.TXT
|
||||
PAGE 9
|
||||
|
||||
8.0 OPERATIONAL VARIATIONS (CON'T)
|
||||
|
||||
THE OUTPUT FILE (IF USED) MAY THEN BE LISTED BY USING THE
|
||||
NORMAL MONITOR COMMANDS (PRINT, LIST, TYPE, PIP, ETC.).
|
||||
|
||||
IF THE PROGRAM IS ABORTED BEFORE COMPLETION (BY ^C, ETC.) THE
|
||||
OUTPUT FILE MAY BE CLOSED BY USING THE MONITOR 'REENTER'
|
||||
COMMAND.
|
||||
|
||||
C. SYSTEM EXERCISER
|
||||
|
||||
START ADDRESS IS 30003. DATA SWITCHES ARE PRESTORED IN
|
||||
'SWTEXR' LOC 30023.
|
||||
|
||||
9.0 MISCELLANEOUS
|
||||
|
||||
THE NON-EX-MEMORY AND PARITY STOP SWITCHES SHOULD BE RESET
|
||||
(0). THESE ERRORS, ILLEGAL UUO'S AND OTHER ERRORS OF THIS
|
||||
TYPE ARE HANDLED BY PRINTOUT ON THE TELETYPE.
|
||||
|
||||
10.0 LISTING
|
||||
```
|
||||
|
||||
DAKAJ.HST
|
||||
---------
|
||||
|
||||
THIS IS A HISTORY OF THE DEVELOPMENT OF MAINDEC-10-DAKAJ
|
||||
|
||||
************************************************************************
|
||||
|
||||
PRODUCT CODE: MAINDEC-10-DAKAJ
|
||||
|
||||
PRODUCT NAME: BASIC INSTRUCTION DIAGNOSTIC #10
|
||||
|
||||
DATE RELEASED: JANUARY 1977
|
||||
|
||||
VERSION: 0.2
|
||||
|
||||
UPDATE AUTHOR: JOHN R. KIRCHOFF
|
||||
|
||||
CHANGES MADE:
|
||||
|
||||
1. UPGRADE TO ALLOW COMPATABILITY WITH THE SUBROUTINE PACKAGE.
|
||||
|
||||
************************************************************************
|
||||
|
||||
VERSION: 1.1
|
||||
|
||||
DATE RELEASED: 09-APR-73
|
||||
|
||||
UPDATE AUTHOR: RICHARD MALISKA
|
||||
|
||||
REASON FOR UPDATE: FIX PROBLEM WITH PROGRAM INITIALIZATION
|
||||
|
||||
************************************************************************
|
||||
|
||||
ORIGINAL VERSION: 0.1
|
||||
|
||||
ORIGINAL AUTHOR: RICHARD MALISKA
|
||||
|
||||
ORIGINAL RELEASE: 16-MAR-72
|
||||
|
||||
************************************************************************
|
||||
|
||||
DAKAJ.MAC
|
||||
---------
|
||||
|
|
|
|||
Loading…
Reference in a new issue