@ -0,0 +1,68 @@
|
|||
---
|
||||
layout: page
|
||||
title: "EKBEE1: 11/70 MEMORY MANAGEMENT DIAGNOSTIC"
|
||||
permalink: /disks/dec/rl02k/xxdp/ekbee1/
|
||||
---
|
||||
|
||||
EKBEE1: 11/70 MEMORY MANAGEMENT DIAGNOSTIC
|
||||
------------------------------------------
|
||||
|
||||
From the [PDP-11 Diagnostic Handbook (1988)](http://archive.pcjs.org/pubs/dec/pdp11/diags/PDP11_DiagnosticHandbook_1988.pdf),
|
||||
p. 1-10:
|
||||
|
||||
11/70 MEMORY MANAGEMENT TEST
|
||||
|
||||
ABSTRACT:
|
||||
|
||||
This program was designed using a "BOTTOM UP" approach starting with the smallest segment of MEMORY MANAGEMMENT
|
||||
logic and building up to cover all the logic. The program begins by testing some of the internal CPU data and
|
||||
address path and address detection logic, then works outward through the MEM. MANAGEMENT registers. It is assumed
|
||||
that both the CPU and the CACHE have been tested, or are known to be good.
|
||||
|
||||
OPERATING PROCEDURES:
|
||||
Set the switch register by <CONTROL P>
|
||||
CON = xxxxxxWZ
|
||||
(W = deposit xxxxxx into console switch register)
|
||||
(R = read and type console switch settings / CON = R)
|
||||
(Z = switch console terminal back to program)
|
||||
|
||||
.R EKBEEI
|
||||
|
||||
SWITCH SETTINGS
|
||||
SW15 = 1 halt on error
|
||||
SW14 = 1 loop on current test
|
||||
SW13 = 1 inhibit all error typeouts
|
||||
SW12 = 1 inhibit trace trapping
|
||||
SW11 = 1 inhibit iterations
|
||||
SW10 = 1 ring bell on error
|
||||
SW09 = 1 loop on error
|
||||
SW08 = 1 loop on test in SWR < 06:00>
|
||||
SW07 = 1 inhibit multiple error typeouts
|
||||
SW06 = 1 selects subtest
|
||||
...
|
||||
|
||||
The closest we have to a source code listing of the EKBEE1 diagnostic comes from some
|
||||
[scanned microfiche](http://archive.pcjs.org/pubs/dec/pdp11/diags/AC-7975E-MC_CEKBEE0_1170_MEM_MGMT_May80.pdf)
|
||||
on [bitsavers.org](http://bitsavers.trailing-edge.com/pdf/dec/pdp11/microfiche/ftp.j-hoppe.de/bw/gh/) for:
|
||||
|
||||
PRODUCT CODE: AC-7975E-MC
|
||||
PRODUCT NAME: CEKBEE0 11/70 MEM MGMT
|
||||
DATE CREATED: MAY, 1980
|
||||
MAINTAINER: DIAGNOSTIC ENGINEERING
|
||||
|
||||
One of the last tests within the diagnostic to pass in PDPjs was "TEST 122: KT BEND", which appears on p. 208 of
|
||||
the PDF (p. 199 of the source code listing):
|
||||
|
||||
;;***************************************************************
|
||||
;*TEST 122 KT BEND
|
||||
;*
|
||||
;* THIS TEST ENSURES THAT TMCE KT BEND GOES LOW ON AN ODD
|
||||
;* ADDRESS ERROR, SL RED, AND NEXM. THIS IS DONE BY EXECUTING
|
||||
;* AN INSTRUCTION FOR EACH Of THESE THESE CASES THAT ALSO
|
||||
;* CAUSES A KT ABORT. THE ABORT SHOULD NOT BE HONORED.
|
||||
;*
|
||||
;* NOTE: ON A KB11-E OR KB11-EM THE KT ABORT SHOULD BE HONORED OVER A
|
||||
;* NEXM TRAP. IF THIS IS A KB11-E/EM THEN THIS FEATURE IS TESTED.
|
||||
;****************************************************************
|
||||
|
||||
|
||||