Removed cycle penalty on AT keyboard controller access. Fixes IBM AT booting at 6 MHz.
This commit is contained in:
parent
adc7728291
commit
a2b1ee68c7
1 changed files with 0 additions and 1 deletions
|
|
@ -445,7 +445,6 @@ void keyboard_at_write(uint16_t port, uint8_t val, void *priv)
|
||||||
uint8_t keyboard_at_read(uint16_t port, void *priv)
|
uint8_t keyboard_at_read(uint16_t port, void *priv)
|
||||||
{
|
{
|
||||||
uint8_t temp = 0xff;
|
uint8_t temp = 0xff;
|
||||||
cycles -= 4;
|
|
||||||
// if (port != 0x61) pclog("keyboard_at : read %04X ", port);
|
// if (port != 0x61) pclog("keyboard_at : read %04X ", port);
|
||||||
switch (port)
|
switch (port)
|
||||||
{
|
{
|
||||||
|
|
|
||||||
Loading…
Reference in a new issue